CP-97-04.3

12

12

12

12

12

9040 Cascade Low Voltage Control Unit - Installation

For installations where it is required to run the AC
input wiring in conduit, perform the following:

1. Ensure the AC line cord is unplugged and
remove the AC Inlet Receptacle wiring from 1TB-
L1, 1TB-N and 1TB-Ground (see Figure 2 for AC
input wiring locations).

2. Remove the mounting hardware from the AC
Inlet Receptacle and remove it from the rear of
the control unit.

3. Install the Conduit Adapter Plate (supplied) in
the hole where the AC Inlet Receptacle was
removed (see Figure 3).

4. Install the AC line cord through the Conduit
Adapter Plate using conduit and wire to TB1 as
follows:

>

When using conduit to route the AC

input wiring to the control unit, the last
several feet of conduit attached to the
control unit should be of a flexible type,
such that the control unit module can still
be slid out of the enclosure for testing and
setup purposes.

N O T E

N O T E

N O T E

N O T E

N O T E

The 9040 Cascade control unit accepts universal
input voltage between 90 and 264 VAC. There is
no need to change any switch settings when
changing input from 115 to 230 VAC or vice-a-
versa.

Figure 2: T

Figure 2: T

Figure 2: T

Figure 2: T

Figure 2: Terminal Block One (1TB)

erminal Block One (1TB)

erminal Block One (1TB)

erminal Block One (1TB)

erminal Block One (1TB)

>

>>

>

> Always double check that the control unit
is unplugged from its AC outlet before working
with any internal wiring connected to 1TB-L1,
1TB-L2, 1TB-N, 1FU, 1SW, or 8PL.

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

!!!!!

Hot/Line

to

1TB-L1

Neutral/Common

to

1TB-N

Ground

to

1TB-Ground

Figure 3: Installation of Conduit

Figure 3: Installation of Conduit

Figure 3: Installation of Conduit

Figure 3: Installation of Conduit

Figure 3: Installation of Conduit

Adaptor Plate

Adaptor Plate

Adaptor Plate

Adaptor Plate

Adaptor Plate

Conduit Adapter Plate

Conduit Adapter Plate

Conduit Adapter Plate

Conduit Adapter Plate

Conduit Adapter Plate

ARCHIVE

Advertising