REA III 100kV Automatic Applicator - Installation

c. Install nut over union stem and start the stem

into the hose.

d. Using the 1/8-inch Allen wrench, screw the

union stem into the hose until it bottoms
against the ferrule.

e. Connect one end of one hose to the appro-

priate fitting on the bottom of the applicator
body and the other end to the power supply
pressure switch for trigger air. Attach the
other hose to the atomizing air source.

Figure 1: Installing Line Hose

Figure 1: Installing Line Hose

Figure 1: Installing Line Hose

Figure 1: Installing Line Hose

Figure 1: Installing Line Hose

Using waterborne coating with electrostatic
equipment requires that the fluid source should
be isolated from ground and other precautions be
taken to ensure operator safety and system
efficiency. The following guidelines should be
followed:

• The fluid lines and source MUST

MUST

MUST

MUST

MUST be isolated

from ground. An isolating paint stand or similar
isolating (non-porous) material MUST

MUST

MUST

MUST

MUST be used.

TYPICAL REA

TYPICAL REA

TYPICAL REA

TYPICAL REA

TYPICAL REA

AUT

AUT

AUT

AUT

AUTOMA

OMA

OMA

OMA

OMATIC APPLICA

TIC APPLICA

TIC APPLICA

TIC APPLICA

TIC APPLICAT

T

T

T

TOR

OR

OR

OR

OR

INST

INST

INST

INST

INSTALLA

ALLA

ALLA

ALLA

ALLATION -

TION -

TION -

TION -

TION -

W

W

W

W

WA

A

A

A

ATERBORNE

TERBORNE

TERBORNE

TERBORNE

TERBORNE

>

NEVER

NEVER

NEVER

NEVER

NEVER use wooden boxes, pallets, or

boards as wood will absorb moisture and is a
poor insulator.

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

!!!!!

• Isolation stand MUST

MUST

MUST

MUST

MUST be at least 18-inches

from the grounded booth wall, chain link fence,
or other grounded objects.

• Air hoses to the pressure pot or pump on the

insulating stand should be nonconductive. Many
rubber hoses will have static grounding circuits
or carbon content and are NOT

NOT

NOT

NOT

NOT suitable.

• Air regulators for pots or pumps should be

mounted remotely outside the fence or cage
area to facilitate changes in pressure without
shutting the system down.

• Grounding hooks at the cage MUST

MUST

MUST

MUST

MUST be used

to ground portions of the system when
personnel are working close by.

• Fluid lines to the applicator MUST

MUST

MUST

MUST

MUST be protected

from scraping and abrasion on the floor or sharp
metal edges that could lead to voltage pinholing
and loss of kV on the charged system.

• Cleanliness and maintenance are extremely

critical.

• Fully discharge system capacitance prior to

service.

>

System capacitance must be fully dis-

charged prior to any service or maintenance of
the applicator.

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

!!!!!

>

ALL charged (isolated) systems MUST

MUST

MUST

MUST

MUST be

inside a fence or cage to prevent contact by
personnel. An interlock system MUST

MUST

MUST

MUST

MUST be

provided that interrupts high voltage flow to the
applicator if the gate is opened.