REA III 100kV Automatic Applicator - Maintenance

>

The valve needle is secured with Lock-

Tite.

N O T E

N O T E

N O T E

N O T E

N O T E

d. Secure control knob [42] in a bench vise

and, with a 1/4-inch wrench on the wrench
flats, break valve needle [47] free and
remove it from the assembly.

>

Apply a light coating of petroleum jelly

to the control knob threads.

N O T E

N O T E

N O T E

N O T E

N O T E

e. Remove spring [46].

f. Unscrew control knob [42] from retaining

nut [43].

g. With a 1/4-inch rod or other small diameter

tool, force washers [45] and o-ring [44] out
of the retaining nut.

2. Assembly:

a. Screw control knob [42] completely into

retaining nut [43].

f.

With a 1/4-inch wrench on the wrench
flats, screw valve needle [47] onto the
control knob shaft. Remove the assembly
from the vise.

g. Unscrew control knob [42] to its “open”

position.

h. Screw retaining nut [43] into the valve

chamber with a 9/16-inch wrench.

>

Apply a light coating of petroleum jelly to

the retaining nut threads.

N O T E

N O T E

N O T E

N O T E

N O T E

i.

Screw the control knob down to the
“closed” position.

T

T

T

T

To Return the Applicator to the

o Return the Applicator to the

o Return the Applicator to the

o Return the Applicator to the

o Return the Applicator to the

Work Site

Work Site

Work Site

Work Site

Work Site

1. Attach the air line fittings to applicator air fittings
[35] and [34].

2. Attach fluid hose to fluid tube fitting [66].

3. Attach and secure the high voltage cable.

4. Turn the power, air, and fluid ON at the source
and return the applicator to service.

High V

High V

High V

High V

High Voltage Cable

oltage Cable

oltage Cable

oltage Cable

oltage Cable

Replacement

Replacement

Replacement

Replacement

Replacement

1. Disassembly:

a.

Unscrew cable retaining nut [32].

b.

Pull the high voltage cable straight out of
the resistor housing.

c.

With a thin blade, lift one end of the cable
retaining ring out of its groove and spiral it
off of the end of the cable.

d.

Remove retainer [32] from the cable.

b. Place one (1) washer [45], o-ring [44], and

the other washer [45] onto the shaft of
control knob [42].

c. Use the flat end of the tubular spanner tool

to seat [45] and [44] in the bore of retaining
nut [43].

d. Place spring [46] onto the shaft of control

knob [42].

e. Secure control knob [42] in the bench vise

and put a small amount of medium
strength Lock-Tite on the shaft threads.