Ransburg REA III Auto Applicator 70393 User Manual

Page 29

Advertising
background image

AA-82-01.3

2 6

2 6

2 6

2 6

2 6

REA III 100kV Automatic Applicator - Maintenance

>

To avoid damage to the chevron seals,

the needle shaft assembly MUST

MUST

MUST

MUST

MUST be in-

stalled from the front of the barrel.

C A U T I O N

C A U T I O N

C A U T I O N

C A U T I O N

C A U T I O N

!!!!!

1. Place female chevron adaptor [6] onto the front
of shaft [7] with the concave side toward the front.

2. Place the four (4) new chevron seals on shaft
[7], concave sides forward, by carefully rotating
them.

>

DO

DO

DO

DO

DO NOT

NOT

NOT

NOT

NOT push the chevron seals

straight onto the shaft. The shaft threads
may damage the chevron bore and cause
the applicator to malfunction.

C A U T I O N

C A U T I O N

C A U T I O N

C A U T I O N

C A U T I O N

!!!!!

3. Place male chevron adaptor [4] onto shaft [7]
with the convex end rearward.

>

Part Items [4], [5], and [6] should seat

together to form an unbroken seal.

N O T E

N O T E

N O T E

N O T E

N O T E

4. Screw needle tip [3] onto shaft [7] hand tight.

5. Insert assembly [3] through [7] into the front
barrel chamber.

6. Insert fluid nozzle [2] into the chamber and
secure it firmly with the nozzle wrench.

7. Screw air nozzle [1] onto barrel [8] to protect
needle [3] during the balance of the assembly
procedures.

8. Place packing tube [25] over the end of shaft
[7] through the rear barrel chamber.

9. Place the new u-cup [18] into rear needle seat
retainer [17] with the open side out.

>

Apply a light coating of petroleum jelly to

the chevron seals.

N O T E

N O T E

N O T E

N O T E

N O T E

>

Seat the u-cup into the retainer very

carefully with the eraser end of a pencil or
a wood or plastic dowel rod.

N O T E

N O T E

N O T E

N O T E

N O T E

10. Place the new o-ring [16] onto retainer [17].

11. Place retainer [17] over shaft [7] with the open
end toward the rear.

12. Place spacer [19] over shaft [7] flanged end
first. Seat parts [15], [17], and [19] into the
chamber carefully with the flat end of the tubular
spanner tool.

13. Place the six (6) spring washers [20] onto shaft
[7] with the first, third, and fifth ones cupped side
rearward and the second, fourth, and sixth ones
cupped side forward.

>

There MUST

MUST

MUST

MUST

MUST be six (6) spring washers,

alternately faced, or the applicator will mal-
function.

C A U T I O N

C A U T I O N

C A U T I O N

C A U T I O N

C A U T I O N

!!!!!

Advertising