REA III 100kV Automatic Applicator - Maintenance

2. Assembly:

a.

Remove the cable retaining ring from the
new cable as in the “Disassembly
Procedure”.

b.

Place retainer [32] over the end of the new
cable.

c.

Place the cable retainer ring over the end
of the cable and with a blade, lift one end
of it into its groove and spiral it into place.

d.

Insert the high voltage cable into the
resistor housing and secure with retainer
[32].