HTP SuperStor Ultra Indirect Fired Water Heaters User Manual

Page 34

Advertising
background image

34

LP-83 Rev. 3.24.14


TROUBLESHOOTING

NO HOT WATER

PROBLEM

POSSIBLE SOLUTION

Zone valve not opening

Open manually to replace.

Circulator not operating

Check or replace

Tank control set too low

Raise tank temperature* (SEE NOTE BELOW)

Boiler control set too low

Raise boiler temperature

Wiring incorrect

Recheck wiring

Tank control failure

Replace control

Zone valve failure

Replace valve

Circulator failure

Replace circulator

Air trap in loop

Purge air

NOT ENOUGH HOT WATER

PROBLEM

POSSIBLE SOLUTION

Zone valve restriction

1” full bore replace zone valve

Circulator arrow reversed

Reverse circulator

Tank temperature too low

Raise tank temperature* (SEE NOTE BELOW)

Boiler temperature too low

Raise boiler temperature

Boiler sized too small

Check sizing chart

Tank sized too small

Check sizing chart

Demand flow rate too high

Install mixing valve, raise tank temperature*

Air trap in loop

Purge to remove air

Install flow regulator

Heat and tank come on together

Recheck wiring or set indirect as priority over central heating.

Draw tank down and lower thermostat. Recheck.

Not enough space heat

Boiler sized too small. Consult chart.

Slow recovery

Circulator head capacity too low

T & P VALVE DISCHARGES

PROBLEM

POSSIBLE SOLUTION

Tank temperature too high

Lower temperature on tank

Water expands when heated

Install expansion tank

Water pressure too high

Install pressure reducing valve

HOT TUBS, SPAS, MULTIPLE SHOWERS, HIGH DEMAND

PROBLEM

POSSIBLE SOLUTION

Pressure too low

Check line pressure for restriction

Recovery of tank slow

Slow startup boiler. See chart.

Not enough hot water

Boiler sized too small. See chart.

Check flow rate and compare to chart

Demand too great. Check flow rates and compare to chart. Install

mixing valve and/or flow restricting valve and raise tank and boiler

temperature*.

Table 10 - *See scald warning below.

When raising tank temperature, the risk of scald injury increases. To avoid scald injury, use a water tempering or mixing valve and
extreme caution when using hot water. Consult codes for conformance.



Advertising