5. Explanation of Operating Functions

40

(4) Acceleration/Deceleration x Enter the acceleration/deceleration at which the actuator will be

moved, in [G].

Basically, you should set values within the rated range specified in the

catalog.

The input range is greater than the rated range in the catalog, in order

to accommodate situations where you want to “shorten the tact time

when the load is much smaller than the rated transferring mass.”

If the load vibrates during acceleration/deceleration and causes

problem, decrease the set values.

Increasing the set value makes acceleration/deceleration quicker, while

decreasing the set value makes acceleration/deceleration more gradual.

Caution: When setting the speed and acceleration/deceleration, refer to 1.5, “Specifications” and

enter appropriate values that will prevent the actuator from receiving excessive impact or

vibration, by considering the installation conditions and shape of the load. Increasing the

speed and acceleration/deceleration changes the transferring mass significantly, and the

actuator characteristics also vary from one model to another. Therefore, consult IAI’s

Sales Engineering Section for the maximum limits that can be entered in your specific

application.

(5) Push

x

Select “positioning operation” or “push & hold operation.”

The factory setting is “0.”

0:

Normal positioning operation

Other than 0: Push & hold operation (The set value defines the

current-limiting value.)

(6) Threshold

x

This field is not used for this controller.

The factory setting is “0.”

(7) Positioning band

x

The meaning of the positioning band varies between “positioning

operation” and “push & hold operation.”

“Positioning operation”

The set value defines the distance before

the target position at which the position

complete signal will turn ON.

Increasing the positioning band quickens

the start of the next operation in the

sequence, meaning that the tact time can

be reduced. Set an appropriate value

based on the overall balance of your

system.

Speed

Acceleration Deceleration

Time

Starting positio

n

Ta

rg

et

positio

n

The position complete

signal turns ON here.

Positioning band

Target

position

Advertising