(2) Controller output signals

(Controller o PLC)

Register

Bit

address

Bit

position

Signal

symbol

Signal name

Description

0100H

15

EMGS

Emergency stop

status

An emergency stop is being actuated when

this bit is “1.”

0101H

14

SFTY

Safety speed

enabled

The safety speed is enabled when this bit

is “1.”

0102H

13

PWR

Controller ready The controller is ready when this bit is “1.”

0103H

12

SV

Servo ready

Operation can be performed at any time

(the servo is on) when this bit is “1.”

0104H

11

PSFL

Missed work part

during push &

hold operation

The actuator has missed the work part

during push & hold operation, when this bit

is “1.”

0105H

10

ALMH

Major failure

status

An alarm is present that inhibits

continuation of operation, when this bit is

“1.”

0106H

9

ALML

Minor failure

status

An alarm is present that permits

continuation of operation, when this bit is

“1.”

8

to

6

-

-

-

010AH

5

STP

Pause command

active

A pause command is being executed when

this bit is “1.”

010BH

4

HEND

Home return

completion

Home return has completed when this bit is

“1.”

010CH

3

PEND

Position complete Positioning has completed when this bit is

“1.”

Device status

register

DSS1

Address

9005H

[Common]

2

to

0

-

-

-

15

to

12

-

-

-

0124H

11

GHMS

Homing

Home return operation is currently in

progress when this bit is “1.”

0123H

10

PUSH

Pushing &

holding

Push & hold operation is currently in

progress when this bit is “1.”

9

to

6

-

-

-

012AH

5

MOVE

Moving

The actuator is moving (during home

return, push & hold operation, etc.) when

this bit is “1.”

Expansion

device status

register

DSSE

Address

9007H

[Common]

4

to

0

-

-

-

Advertising