Part 4 Commands


 SLWK (Select load coordinate system)

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command, declaration

Output

(Output, flag)

Command,
declaration

Operand 1

Operand 2

Optional

Optional

SLWK

Load coordinate

system number

Prohibited

CP

[Function] Set the value specified in operand 1 as the selected load coordinate system number.

Refer to 3, "Coordinate System," in Chapter 3 of Part 4.


(Note 1)

The number declared last in the system becomes valid.
The selected load coordinate system number will remain valid after the program ends, or
even after reconnection of power if a system-memory backup battery is installed.


(Note 2)

Only one load coordinate system number can be selected in the system.

(Note 3)

Expressly declare SLWK in the program to prevent problems that may occur when the
coordinate system number changed via the PC software or teaching pendant was not
returned to the original setting.
(Set SLWK = 0, if load coordinate system is not used.)