IAI America XSEL-KX User Manual

Page 194

Advertising
background image




178

Part 4 Commands


 TMPI (Move relatively between positions on tool coordinate system)

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command, declaration

Output

(Output, flag)

Command,
declaration

Operand 1

Operand 2

Optional

Optional

TMPI

Position

number

Prohibited

PE

[Function] Each axis will move relatively on the tool coordinate system without interpolation (= PTP

operation) based on the position data specified in operand 1 setting the travel amount from
the current position.


(Note 1)

Repeated use of incremental (relative) movement commands will accumulate coordinate-
conversion rounding errors.

[Example]

TMPI

120



Position data


































Tool coordinate home
after movement

Tool coordinate home
before movement

Yt1

Yt1

-Yt1

30

60

-30

°

Xt1

Xt1

Advertising