Scon-ca cc-link, Scon-ca applicable to cc-link actuator – IAI America PCON-CFA User Manual

Page 163

Advertising
background image

5. SCON-CA

CC-Link

157

4) Full Direct Value Mode: This is the operation method with all the values (“Target Position”, “Speed”,

“Acceleration/Deceleration”, etc.) related to the position control set up directly using
the numerical values.
No. of Occupied Stations: Four Stations

5) Remote I/O Mode 2: This is the operation method using CC-Link, instead of PIO (24V I/O).

The current position and command current value reading functions are added to the
functions of (1).
No. of Occupied Stations: One Station

6) Position/Simplified Direct Value Mode 2: This is the operation method with the position No. set up.

This is a mode that provides the force control function instead of
teaching and zone functions in 2).
No. of Occupied Stations: One Station

Target Position : 100.00mm

Positioning Width : 0.10mm

Speed Setup : 100.0mm/s

Acceleration : 0.30G

Deceleration : 0.30G

Pressing Current Value : 50%

Load Current Threshold : 0

Zone + : 50.00mm

Zone - : 30.00mm

SCON-CA

applicable to CC-Link

Actuator

SCON-CA

not applicable to CC-Link

SCON-CA

applicable to CC-Link

Flat cable

Communications

cable

In the case of the connection using PIO

In the case of the connection using CC-Link

Target Position : 100.00mm

+

Position No.0

SCON-CA

applicable to CC-Link

Actuator

No.

0

Speed

[mm/s]

Acceleration

[G]

Deceleration

[G]

Pressing

[%]

300.00

0.30

0.30

0