5. SCON-CA

CC-Link

176

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal Type

Bit Symbol

Description

Details

Current

Position

32bits



Current Position: 32-bit Signed Integer
The unit is 0.01mm.
(Example)
Read Value: 000003FF

H

= 1023 (decimal system) = 10.23mm

When the value is read in hexadecimal notation, the negative
figure is expressed as a compliment of 2.

5.9 (1)

Completed

Position

No.

(Simplified

Alarm

CODE)

16bits

PM1 to
PM512

16-bit Integer
It is moved to the target position and the positioning completed
position No. within the positioning width is output.
In the case that the position movement has not been performed
at all, or during the movement, “0” is output.
When an alarm is issued (in the case that the status signal ALM
is “ON”), the simplified alarm code (Refer to the instruction
manual for the controller main body) is output.

5.9 (1)

b15

EMGS Emergency Stop: “ON” for Emergency Stop Status

5.7.11 (2)

b14

PWR Controller Ready: “ON” for Ready

5.7.11 (1)

b13 ZONE2 Zone 2: “ON” with the current position within the zone set range 5.7.11 (12)
b12 ZONE1 Zone 1: “ON” with the current position within the zone set range 5.7.11 (12)

b11

PZONE

Position Zone:
“ON” with the current position within the position zone set range

5.7.11 (12)

b10 MODES

Teaching Mode Signal;
“ON” during teaching mode selection

5.7.11 (16)

b9

WEND

Position Data Import Completion:
“ON” for import completion

5.7.11 (17)

b8

RMDS

Operation Mode Status:
“OFF” for currently “AUTO” mode, “ON” for currently “MANU”
mode

5.7.11 (19)

b7

BALM

Warning for Absolute Battery Voltage Drop :
Turns ON at voltage drop

5.7.11 (28)

b6



Unavailable



b5

PSEL Pressing and a Miss: “ON” for pressing and a miss

5.7.11 (23)

b4

SV

Operation Ready: “ON” with Servo ON

5.7.11 (5)

b3

ALM Alarm: “ON” with alarm issue

5.7.11 (3)

b2

MOVE

Under Movement Signal:
“ON” during Actuator Movement

5.7.11 (9)

b1

HEND

Homing Completion
“ON” with Homing Completion

5.7.11 (6)

P

LC

In

pu

t

Status
Signal

b0

PEND

Positioning Completion Signal:
“ON” with Positioning Completion

5.7.11 (10)