2.

Wiring

2.2 PIO Pattern Selection and PIO Signal

(1) Operation Pattern

The 6 operation patterns (For PIO Pattern). Each of these 6 patterns is described as in the table. Also,

the corresponding air cylinder circuit is described for reference.

Operation Pattern

Contents

Example for Electric Cylinder

Connection

Example for Air Cylinder

Connection (Reference)

PIO Pattern 0
Single Solenoid System
(Standard Point-to-Point

Movement)

The actuator point-
to-point movement is
available using the same
control function as for
the air cylinder.
The target position
setting (forward position
and backward position)
is available.
Speed and acceleration
settings in the actuator
movement are available.
The pressing operation
is available.

PLC

+24V

ASEP,
PSEP,
DSEP

Electric Cylinder

Dedicated
Cable

Movement Signal

(ST0)

Backward
Position Detection
(LS0)

Forward
Position Detection
(LS1)

R2

R1

B

A

Spring

Solenoid

Air Cylinder

PLC

Movement Signal

(ST0)

P(Air)

Forward
Position Detection
(LS1)

Backward
Position Detection
(LS0)

PIO Pattern 0
Double Solenoid System
(Standard Point-to-Point

Movement)

+24V

ASEP,
PSEP,
DSEP

Electric Cylinder

Dedicated
Cable

PLC

Backward Position

Movement Signal

(ST0)

Forward Position

Movement Signal

(ST1)

Backward
Position Detection
(LS0)
Forward
Position Detection
(LS1)

R2

R1

B

A

Solenoid

Solenoid

Air Cylinder

PLC

P(Air)

Movement Signal

(ST0)

Forward Position

Movement Signal

(ST1)

Backward
Position Detection
(LS0)
Forward
Position Detection
(LS1)

PIO Pattern 1
Single Solenoid System
(Point-to-Point Movement)
(Movement Speed Setting)

The actuator point-
to-point movement is
available using the same
control function as for
the air cylinder.
The speed change in the
movement operation is
available.
The target position
setting (forward position
and backward position)
is available.
Speed and acceleration
settings in the actuator
movement are available.
The pressing operation
is available.

+24V

ASEP,
PSEP,
DSEP

Electric Cylinder

Dedicated
Cable

PLC

Movement Signal

(ST0)

Movement Speed

Change Signal

(SPDC)

Backward
Position Detection
(LS0)

Forward
Position Detection
(LS1)

Spring

R2

R1

B

A

Solenoid

Air Cylinder

PLC

P(Air)

Movement Signal

(ST0)

Movement Speed

Change Signal

(SPDC)

Backward
Position Detection
(LS0)

Forward
Position Detection
(LS1)

PIO Pattern 1
Double Solenoid System
(Point-to-Point Movement)
(Movement Speed Setting)

+24V

ASEP,
PSEP,
DSEP

Electric Cylinder

Dedicated
Cable

PLC

Backward Position

Movement Signal

(ST0)

Forward Position

Movement Signal

(ST1)

Movement Speed

Change Signal

(SPDC)

Backward
Position Detection
(LS0)
Forward
Position Detection
(LS1)

R2

R1

B

A

Solenoid

Solenoid

Air Cylinder

PLC

P(Air)

Backward Position

Movement Signal

(ST0)

Forward Position

Movement Signal

(ST1)

Movement Speed

Change Signal

(SPDC)

Backward
Position Detection
(LS0)
Forward
Position Detection
(LS1)