2.4.4 Connection of PIO

Conduct the connection of I/O to the controller is to be carried out using the dedicated I/O cable. The

cable length is shown in the model code of the controller. Please check the controller model code.

There are 2m for standard, 3m and 5m as an option. 10m is also applicable at maximum if purchased

separately. [Refer to “1.1.5. How to read the model]

Also, the end of the cable harness to be connected to the host controller (PLC, etc.) is just cut and no

treatment is conducted so the wiring layout can be performed freely.

0RGHO&%$36(33,2ƑƑƑÂÂÂ)RU$6(3&36(3&

ƑƑƑVKRZVWKHFDEOHOHQJWK/([DPSOH 2m)

Ɣ 3,2&RQQHFWRU

Applied Connector

55959-1030

Manufactured by MOLEX

Connector Name

I/O

PIO Connector

Connection Cable

Dedicated Cable [refer to (3) in this

section.]

Enclosed in this controller

L

10

2

1

9

0RGHO&%$36(3:3,2ƑƑƑÂÂÂ)RU$6(3&:36(3&:

ƑƑƑVKRZVWKHFDEOHOHQJWK/([DPSOH 2m)

L

10

2

1

9

Connector

51353-1000 (Manufactured by MOLEX)

No.

Color

Signal Name

CB-APSEP-PIO

ƑƑƑ

CB-APSEPW-PIO

ƑƑƑ

1

BR

BR

24V

2

RD

BR, WT

0V

3

OR

RD

IN0

4

YW

RD, WT

IN1

5

GN

YW

IN2

6

BL

YW, WT

IN3

7

PL

GN

OUT0

8

GY

GN, WT

OUT1

9

WT

BK

OUT2

10

BK

BK, WT

OUT3