3.
Operation

Note:

Regarding to Acceleration/Deceleration Speed Setting
  'RQRWKDYHWKHVHWWLQJWRH[FHHGWKHUDWHGDFFHOHUDWLRQGHFHOHUDWLRQVSHHGWKDWLVVSHFL¿HG

in the catalog or this Instruction Manual. The setting that exceeds the rated acceleration/

deceleration speed may shorten the actuator life remarkably.

(2) Consider to lower the acceleration/deceleration speed when a shock or vibration is applied to

the actuator or work. In such a case, keeping the use under such a condition may shorten the

actuator life remarkably.

5) Pressing Force … Set the pressing torque (current limit value) in % for the pressing operation.

Having a bigger power limit value gives bigger pressing force.

It is set to the positioning operation when setting to “0”.

[Refer to Appendix in this manual or the Instruction Manual for the actuator.]

Setting Range : 0 (pressing operation is disabled), 20 to 70%

(Note 1)

(Unit: 1%)

It differs depending on the actuator.

[Refer to Appendix in this manual or the Instruction Manual for the actuator.]

6) Pressing Width … Set the position for starting the pressing operation.

The position moved as much distance as the pressing width to the center

from the movement target position (forward position or backward position), is

regarded as the starting position, the pressing operation is started.

Pressing Width

Actuator Operation

(2) Setting by Speed

(1) Setting by Position

Set the pressing speed in Parameter No. 7

Pressing operation completes when the
pressing force reaches the specified value within
the pressing band range.

Velocity

Time

Pressing Width

Pressing Complete

(Positioning complete

signal output)

Pressing

Start Position

[Pressing towards Forward Position or Intermediate Position]

Backward

Position

Forward Position

(Intermediate Position)