Chapter 3 Operation

POWER CON

PCON-CA/CFA

115

3) First define the positioning in position No.1. Next, the operation in position No.2 moves the

actuator to the position of 80mm at the setting speed and rating torque and change to the

tension operation. The actuator moves by 50mm in the negative direction in the tension

operation. The upper limit of the tensile force is the torque set in percent.

4) In the similar way as pressing, the positioning complete signal is output when the shaft is

stopped by tension (pressing complete). If the actuator cannot be stopped during

movement within the setting positioning width (miss-pressing), it moves by the setting

distance to stop but PEND is not turned ON. The current position No. PE* is turned on at

the completion of pressing and even in miss-pressing.

 

Caution: (1) The speed during tension operation is set in Parameter No.34. [Refer to

9.5 List of Specifications of Connectable Actuators for the pressing speed.]

Do not set any value larger than the value in the list. If the speed set in the

position table is equal to or less than the tension speed, the tension

operation is performed at the setup speed.

(2) The tension ready position should be the tension start position or forward. If

not, the moving direction varies depending on the start position to be

dangerous.

The tension operation from a coordinate (less than 30mm = 80 – 50)

located before the end position (30mm) changes to the pressing operation

from the current position to the tension end position. Note that the tension

operation after positioning to the position of 80mm does not take place.

(3) The work is pulled also after completion of the tension. The work is drawn

back or pulled further if the work is moved. When the work is drawn back

before the approach position, alarm code 0DC “pressing operation range

error” occurs to stop the work. When the work is moved in the tension

direction and the load current becomes less than the current limit value

(pressing in percent), PEND is turned OFF. Naturally, the work reaches the

tension moving distance set in “Positioning width” to cause miss-pressing.

(4) Pulling operation cannot be performed with the rotary actuator.

Command Torque Level Detection at Pulling [Function dedicated for High-Thrust Actuator Type]

It is available to use in the same manner as for pressing. [Refer to Pressing Operation in

3.2.5 [3] Position Number Input Operation = PIO Pattern 4.]

Pressing Operation

ST*: Start position

ST*

ST*

ST*

Tension Operation

Approach Operation

Tension Operation

Tension start position

80mm

Temsion end position

80 – 50 = 30mm