Alliance Laundry Systems CABINET FREESTANDING 9001889R7 User Manual

Page 13

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming

11

9001889

Chemical Hold Feature
Chemical supply injection can be paused. Refer to

Setup of Chemical Hold Feature.
Wash 5 Thermal Cool-Down
Immediately after a heat step, a temperature-controlled

thermal cool-down may be programmed to prevent

fiber shock from sudden cool-down.

The “Heat” button is number 5.
Example: Heat up to 140°F with the time limit of

45 minutes.

Step XX Cycle XX
Wash

Step XX Cycle XX
0°F (or 0°C)

Step XX Cycle XX
Wash 5

Enter desired temperature for load to

cool down to. Three digits must be used

for temperature. If Fahrenheit, the valid

temperature range is 80° – 200°F. If

Celcius, valid temperature range is

25° – 90°C (example: 95°F).

Step XX Cycle XX
95°F

Step XX Cycle XX
0 hours

Step XX Cycle XX
1 hours 00 min

Thermal Cool-Down

is Wash 5.

Step XX Cycle XX
1 hours 05 min

Enter time in minutes

and press “Enter”

(example: 5 min).

Step XX Cycle XX
Heat

Step XX Cycle XX
0°F

Step XX Cycle XX
140°F

Step XX Cycle XX
0 hours 45 min

Step XX Cycle XX
0 hours

Advertising