Programming

9001889

6

Press “Enter” to set the hysteresis level (level at which

water drops before it senses it must refill).
If English is selected for units, this value will be in

inches. If Metric is selected for units, this value will be

in cm.
Select between 1 to 9 cm or inches.
Press “Enter” to select the temperature hysteresis

(level at which temperature drops before machine

senses it must reheat).

If English is selected for units, this value will be in °F.

If Metric is selected for units, this value will be in °C.

Select 1 to 9 °C or °F.

Press the “Enter” button to set the spin retries.

Select 1 to 9 spin retries.

Press “Enter” to set the network address of the

machine. If this is not used, press “Enter”.

The address of the machine has to be set if you

network the machine. Each machine should have a

different address.
Fill in between 00 and 99.
Press “Enter” to finish the settings.
Press “Enter” to save the settings or press “Stop” to

exit without saving.

Level : hyst 2"

Enter to save ?

Program Cycle 00

Temp : hyst 3°F

Spin retries : 5

Address : 0