Calibration of the machine – Alliance Laundry Systems CABINET FREESTANDING 9001889R7 User Manual

Page 30

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming

9001889

28

Calibration of the Machine

The _x__PV should reflect the size selected in earlier

steps.
Turn key to Program Mode.

Press “Auxiliary”, “3”, “1”.

The total hours the machine was running will be

displayed.
Press “Advance” and screen will show total cycles.
Press “Advance” to calibrate the water level sensor.
If the value is not zero, press “Enter” and the value

will change to zero.

Press “Advance” to calibrate the motor.
The board will lock the door and let the motor spin at

approximately 500 rpm (Firmware version 1.12 or

higher). The rpm will increase on the display. If the

machine reached approximately 500 rpm, the display

will show a reference value.
After the reference value is shown, the machine will

coast down to stop. When the machine stands still, the

board will unlock the door.

Program Cycle 00

Total working
hours : 0

level : 0.0 “
Enter to zero

Spin
XXX rpm

Reference x.xx

Advertising