Teledyne LeCroy Summit T3-16 PCIe Multi-lane Protocol Analyzer User Manual User Manual

Page 118

Advertising
background image

Teledyne LeCroy

Probe Settings

106

 

 

Summit T3‐16 PCI Express Multi‐Lane Protocol Analyzer User Manual

Figure 5.56: Dashboard View

Note:

You can also set the recording option for auto configure lane polarity to unchecked and set up 

the polarity manually after reviewing the training sequences shown in the CATC Trace (refer to 
http://cdn.teledynelecroy.com/files/appnotes/lane_reversal_and_polarity.pdf). In this case, do 
not open the Dashboard dialog and go directly to step 6.

4. Copy the calculated polarity from the Dashboard to the Recording Options by 

clicking the Copy Polarity Settings to Recording Options button.

Figure 5.57: Calculating Optimal CTLE Progress Bar

5. Close the Dashboard and verify that the lane polarity in Recording Options have 

been updated. You will need to keep using this configuration after the calibration 
has been performed.

6. Drive the link to Gen3 and make sure the link stays in Gen3 L0 (no low power states 

or speed switch).

7. Select Recording Options and click the Probe Settings tab. 
8. Click Auto Configure to display the Calibrate SummitT3‐8 Dialog.

Manually set the polarity for each lane in this dialog with the polarity settings in the 
Link Dashboard. Link Width, Speed and Polarity must be set the same as the current 

Advertising