183

Error Summary

  Teledyne LeCroy

Figure 10.4: AHCI Error Summary Dialog

The five types of AHCI errors are describe below:

Reserved Field not Zeroes

One or more fields inside the AHCI transaction are not filled with all 0s. The AHCI 
specification states that all reserved fields and registers must be filled with 0s.

Figure 10.5: Reserved Field Not Filled With Zeroes

Note:

Reserved fields for AHCI level are not displayed when filled with all 0s.

Incomplete

The AHCI transaction does not contain enough data or lower‐level transactions (Link or 
Split) are marked as incomplete.

Figure 10.6: Incomplete

Logical Error 

One or more fields are in an inconsistent state relative to the other fields in the same or 
other registers.

Figure 10.7: Logical Error