7- Main Power Down:


Set Main Voltages to Off, this routine disables the mechanical switch. To enable the mechanical switch the power to
the extender board has to be turned off and then on.


Use the "Set Address" routine to set address

DUT 1 = 0x64

DUT2 = 0xe4

use write routine to write

0x1

8- +5V Aux Up


Be sure to have the Global register to on before turning any voltages on or off

Use the "Set Address" routine to set address

DUT 1 = 0x65

DUT2 = 0xe5

use write routine to write

0x0

9- +5V Aux Down:


Use the "Set Address" routine to set address

DUT 1 = 0x65

DUT2 = 0xe5

use write routine to write

0x1

10- +3.3V Aux Up:


Be sure to have the Global register to on before turning any voltages on or off

Use the "Set Address" routine to set address

DUT 1 = 0x66

DUT2 = 0xe6

use write routine to write

0x0

11- +3.3V Aux Down:


Use the "Set Address" routine to set address

DUT 1 = 0x66

DUT2 = 0xe6

use write routine to write

0x1

12- RST# setup:


Data[20..0] provides a delay time up to 5.368709 seconds in 2.56 microseconds increment.


D23 = 0, sets the reset time to default of about 150 ms
D23 = 1, sets the reset time to the value defined by D0 to D20

Use the "Set Address" routine to set address

DUT 1 = 0x71

DUT2 = 0xf1

use write routine to write D[7..0]

Use the "Set Address" routine to set address

DUT 1 = 0x72

DUT2 = 0xf2

use write routine to write D[15..8]

Use the "Set Address" routine to set addres s

DUT 1 = 0x73

DUT2 = 0xf3

use write routine to write D[23, 20..16]