Jumpers, pcibx – Teledyne LeCroy PCIBX64-X User Manual

Page 8

Advertising
background image

6

JUMPERS, PCIBX


SW

Installed => Mechanical switch may be used to control the extender, so long as software control has not
been used. (Default)

Not Installed => Mechanical switch is disabled


JP15

Installed => PCIBX board ID is PCI_1 (Default)

Not Installed => PCIBX board ID is PCI_2


JP3

Installed => UUT I/O signals = System VIO

Not installed => Allows UUT and systems of different VIO voltages (5V and 3.3V)

to operate together (Default)


JP4

Installed =>

-12V source is from the system.

Not Installed => -12V source is from the external input.


JP5

Installed =>

+5V source is from the system.

Not Installed => +5V source is from the external input.


JP6

Installed =>

+12V source is from the system.

Not Installed => +12V source is from the external input.

JP7

Installed 1-2 => +3.3V to UUT is from On-board source.

Installed 2-3 => +3.3V to UUT is from system.

Not installed => +3.3V to UUT should be from the external source.


JP10

Installed => UUT VIO is connected to the system VIO.
Not Installed (Default) => UUT VIO not connected to the system VIO, but connected to the UUT

power plane.

JP16

For factory use only.


JP17

Installed between 1 and 2 => PCI-X enable signal driven by the UUT.

Installed between 2 and 3 => PCI-X enable signal set to 66 MHz.

Not installed => PCI-X enable signal is not supported (Default)


J4

Factory use.

Advertising
This manual is related to the following products: