Serial data debug solutions 114 – Teledyne LeCroy Serial Data Debug Solutions User Manual

Page 114

Advertising
background image

Serial Data Debug Solutions

114

919586 RevA

TxCmd1 Right-Hand Dialog - Provide values for the RT and Sub Address fields complete with Condition,
Value, To (for range conditions), and T/R controls. Word Count/Mode Code fields include Condition and
Word Count (amount) controls.

RxCmd2 Right-Hand Dialog - Provide values for the RT and Sub Address fields complete with Condition,
Value, To (for range conditions), and T/R controls. Word Count/Mode Code fields include Condition and
Word Count (amount) controls.

DW Right-Hand Dialog - Provide Data Pattern Setup field values for Data Condition,Start Bit and # Data
Bits
, Data Value and Data Value To (for range conditions).

TxStat1 Right-Hand Dialog - Provide RT Address field values for Condition, Value and To (for range
conditions). Select Status Word Setup values (0, 1, or X) for Error, Instr, SRQ, Bcast Rcvd, Busy, Sub Syst,
Dyn Bus, and Term Flg.

Mode command (B'cast) Sub-Type and Right-Hand Dialogs

When the Mode command (B'cast) sub-type is selected, the TxCmd1 right-hand dialog is made available.

Note: Different combinations of similar right-hand dialogs are made available for the various Sub-Types. See

BC-RT (Rcv) Sub-Type Right-Hand Dialogs

for screen-shots. Otherwise, provide field information as directed

verbally.

TxCmd1 Right-Hand Dialog - Provide values for the RT and Sub Address fields complete with Condition,
Value, To (for range conditions), and T/R controls. Word Count/Mode Code fields include Condition and
Mode Code controls. Select from 32 possible Mode Code values:

Mode Code Field Values

Dynamic Bus
Control

Synchronize

Transmit Status
Word

Initiate Self Test

Transmitter
Shutdown

Override
Transmitter
Shutdown

Inhibit
Terminal Flag

Override Inhibit
Terminal Flag

Reset Remote
Terminal

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved


Transmit
Vector Word

Synchronize

Transmit Last
Command

Transmit BIT
Word

Selected
Transmitter
Shutdown

Override Selected
Transmitter
Shutdown

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

Mode command & Data (B'cast) Sub-Type and Right-Hand Dialogs

When the Mode command & Data (B'cast) sub-type is selected, the RxCmd1 and DW right-hand dialogs are
made available.

Note: Different combinations of similar right-hand dialogs are made available for the various Sub-Types. See

BC-RT (Rcv) Sub-Type Right-Hand Dialogs

for screen-shots. Otherwise, provide field information as directed

verbally.