Storage, peripherals, and interconnect protocols, Fibre channel, Sata – Teledyne LeCroy Serial Data Debug Solutions User Manual

Page 154: Pcie, Serial data debug solutions 154

Advertising
background image

Serial Data Debug Solutions

154

919586 RevA

Storage, Peripherals, and Interconnect Protocols

Storage, Peripherals, and Interconnect Protocols Overview

SAS

The

SAS

computer bus standard was initially designed to transfer data off and onto hard and tape drives. SAS

also has backward compatibility from second-generation SATA drives; meaning SATA 3 Gb/s drives may be
connected to SAS backplanes, but not vice versa.

Standards are maintained by T10 Technical Committee of the InterNational Committee for Information
Technology Standards (incits)
. Specification information can be found at

http://www.t10.org/

. 1.5, 3 and 6

Number of Lines

Data rate

Synchronous or Asynchronous

2 (differential)

1.5 Gb/s

3 Gb/s

6 Gb/s

Asynchronous

Fibre Channel

Starting out as a solution to simplify connections and increase transfer distances,

Fibre Channel

evolved into a

standard designed to connect SCSI disk storage (among other connected devices) and increasing transfer speeds.

Standards vary based on protocols/variants and are maintained by Joint Technical Committee 1 of the
InterNational Committee for Information Technology Standards (incits). Specification information can be found
at

http://standards.iso.org/ittf/PubliclyAvailableStandards/index.html

.

Number of Lines

Data rate

Synchronous or Asynchronous

2 (differential)

1.0625 Gb/s

2.125 Gb/s

4.25 Gb/s

8.5 Gb/s

14.025 Gb/s

Asynchronous

SATA

Typically used to connect host bus adapters to hard drives and optical drives, Serial Advanced Technology
Attachment, or

SATA

replaced the AT Attachment, or ATA protocol. SATA made great improvements on its

predecessors by reducing the number of connecting wires, providing more efficient and faster data transfers,
and allowing for hot swap connections.

The standard is maintained by the Serial ATA International Organization. Additional information, including the
specification, can be found at

www.sata-io.org/

.

Number of Lines

Data rate

Synchronous or Asynchronous

1 (differential)

Up to 6 Gb/s

Synchronous