Device Scope PeRT3 (Host TX and RX Tests)

This configuration is meant to run all of the transmitter and receiver tests for a user that has a PeRT

3

but not the

RF Switch. All of the variables are set to default except Product Type is set to

“Device”, Use PeRT3 is set to

“Yes” and Channel File is set to “Host11inWith3mCable.s4p.” The limit set used is ComplianceLimits. The tests
that are run are:

Test 1.1

– Low Frequency Periodic Signaling

Test 1.2

– Spread Spectrum Tests

Test 1.3

– Jitter & Eye Diagram Tests

o Test 1.3.1

– Jitter

o Test 1.3.2

– Phase Jitter Slew Rate

o Test 1.3.3

– SigTest Jitter

o Test 1.3.4

– Eye Diagram

o Test 1.3.5

– SigTest Eye Diagram

Test 1.4

– AC & DC Common Mode Test

Test 1.5

– Differential Voltage & De-emphasis Test

Test 2.1.

– Jitter Tolerance Test

Device Scope PeRT3 (Host TX Tests)

This configuration is meant to run all of the transmitter tests for a user that has a PeRT

3

but not the RF Switch. All

variables are set to default except Product Type (set to

“Device”), Use PeRT3 (set to “Yes”) and Channel File

(set to

“Host11inWith3mCable.s4p”). The limit set used is ComplianceLimits. The tests that are run are:

Test 1.1

– Low Frequency Periodic Signaling

Test 1.2

– Spread Spectrum Tests

Test 1.3

– Jitter & Eye Diagram Tests

o Test 1.3.1

– Jitter

o Test 1.3.2

– Phase Jitter Slew Rate

o Test 1.3.3

– SigTest Jitter

o Test 1.3.4

– Eye Diagram

o Test 1.3.5

– SigTest Eye Diagram

Test 1.4

– AC & DC Common Mode Test

Test 1.5

– Differential Voltage & De-emphasis Test

Device Scope PeRT3 RF Switch (Host RX Tests)

This configuration is meant to run all of the transmitter tests for a user that has a PeRT

3

and the RF Switch. All

variables are set to default except Product Type (set to

“Device”), Use PeRT3 (set to “Yes”), Use RF Switch (set

to

“Yes”), Channel File (set to “Host11inWith3mCable.s4p”) , De-embed Cables (set to “Yes”) and Cable S-

Parameters File

(set to “green24white12.s4p”). The green24white12.s4p file is installed with QualiPHY and is

appropriate for de-embedding the 24inch green cables and 12 inch silver cables with white label that are included
as part of the USB3-TX-RX bundle. The limit set used is ComplianceLimits. The tests that are run are:

Test 2.1.

– Jitter Tolerance Test