8

The standard beeping tone is also an indication of sensitivity level .

- In HIGH sensitivity the unit emits two quick beeps approximately once every two (2)

seconds, in fresh air .

- In LOW sensitivity the unit emits only one beep, approximately once every two (2)

seconds, in fresh air .

sensor status indicator

The unit’s circuit has the ability to automatically diagnose and indicate the sensor’s

status . Whenever the unit is energized, the circuit automatically senses the condition

of the sensor and can detect a failed or missing sensor .

Old Sensor Indication: As the sensor ages, the circuit will note and indicate this to the

user . Initially, an Old Sensor Indication is displayed by flashing the Constant Power

Indicator . If this indication appears, it is time to obtain a replacement sensor . Refer to

the Replacement Parts section . However, it is not necessary to replace the sensor

before the Failed Sensor Indication is received .

Failed Sensor Indication: If the circuit detects a failed or missing sensor, the 2nd

through 6th LEDs turn red and flash quickly . The 1st LED continues to display the

battery status as described earlier . Additionally, the internal pump shuts down to

prevent unnecessary battery drain . If this indication appears, refer to the Maintenance

section for service instructions .

audible / Visual alarms – Mute feature

The unit features two primary alarm indications – an internal speaker that produces a

multiple frequency tone, and a series of tri-color LEDs that provide an incremental

indication of leak detection and proportional leak size .

You may choose to activate both the audible and visual alarms, or use only the visual

alarm . Upon power-on, the unit will activate both . If you wish to cancel or “mute” the

audible alarm, press the Alarm Key .

This mutes the internal speaker, and detection will be indicated solely by the LED

display . Press the Alarm Key again, at any time, to reactivate the internal speaker .

The LEDs provide a tri-color, proportional indication of leak intensity . The 2nd through

6th LEDs are used for this indication, while the 1st LED always remains an indication

of battery strength . See Figure 5 .

Advertising