Specifications – TIF ZX Heated Pentode Refrigerant Detector User Manual

Page 19

Advertising
background image

17

Sensor Technology:

Heated Pentode

TM

(advanced heated diode)

Electronic Technology: Microprocessor-controlled circuit, including constant

battery and sensor condition detection

Sensitivity:

Per SAE J1627 criteria; 0 .5 oz/yr (14 gr/yr) for R134a,

R22, and R12

Ultimate Sensitivity:

High sensitivity—less than 0 .1 oz/year (3 gr/yr) R134a

Low sensitivity—as low as 0 .05 oz/yr R12 (< 30% RH)

Warm-up Period:

20 seconds

Excessive Refrigerant

Tolerance:

Sensor cannot be poisoned by excessive refrigerant

Battery Life:

5 to 6 hours, depending on sensor age

Battery Technology:

NiMH

Battery Recharge Time: 2 hours, integral charge status indication
Failed Sensor

Indication:

All LEDs flash red, pump off

Sensor Life:

Approximately 100 hours under normal use

Operating

Environment:

32°F to 122°F (0°F to 50°C), 0 to 95%

RH non-condensing

Dimensions:

10 .25" lg . x 2 .5" dia . (26 cm lg . x 6 .5 cm dia .)

Weight:

Approximately 16 ounces (452 grams)

sPecifications