Operation – TIF ZX Heated Pentode Refrigerant Detector User Manual

Page 11

Advertising
background image

9

When a refrigerant is detected, the visual indicator lights from left to right; first in

green, then sequentially in orange, and then sequentially in red . Often, on anything but

the smallest leak, the extreme sensitivity of the unit may cause the LEDs to all light in

orange or red . Since each LED can appear in one of three colors – green, orange or

red – this will result in 15 distinct alarm levels .

WaRninG: to prevent personal injury, do not use this leak Detector in

an explosive or combustible atmosphere. ambient atmosphere is drawn

through the probe and sensor, which operate at a very high temperature.

the resulting hot mixture of air and combustible gas could explode.

1 . Press and release the ON/OFF Key to switch the unit on .

2 . The LEDs begin cycling in orange, from left to right, to indicate warm-up . The warm-

up time is fixed at 20 seconds .

3 . After warm-up, all LEDs briefly flash orange, indicating the unit is ready for use . The

unit begins beeping at a steady rate (two quick beeps approximately once every two

seconds – indicating HIGH sensitivity) . The first LED displays the battery voltage

level as described in the Constant Power Indicator section .

4 . Set the sensitivity level you wish to use, as described in the Sensitivity Adjustment

section .