TIF ZX Heated Pentode Refrigerant Detector User Manual

Page 7

Advertising
background image

5

Once the battery pack has been installed, plug the battery charger into a wall outlet

and connect the charger jack to the unit (see Fig . 3) . When correctly connected, the

first LED will indicate charging status:

Quickly flashing orange = battery charging

Slowly flashing green = battery fully charged

Slowly flashing red = failed batteries; cannot be recharged

New or completely discharged batteries will take approximately two (2) hours to fully

recharge . When the LED indicates the batteries are fully charged, the unit is ready for

operation .

sensor and Probe installation

A new unit comes shipped with the probe not installed on the unit, and the sensor

packaged in a sealed foil bag .
1 . Open the bag and remove the sensor .

2 . Hold the unit with the front end facing you and note the sensor connection inside

the threaded bushing on the end of the unit . There are five (5) holes corresponding

to the five (5) pins on the sensor – three (3) on the left and two (2) on the right

(refer to Fig . 4) .

3 . Align the pins in the sensor with the corresponding holes in the threaded bushing .

When correctly aligned, firmly push the sensor into the bushing until it stops .

4 . Install the flexible probe by threading it clockwise onto the threaded brass bushing

around the sensor until it is finger tight .

caution: to prevent personal injury and equipment damage, neVeR

operate the unit without the flexible probe correctly installed. sensor

contamination, erratic performance, and other problems may occur.

additionally, the sensor will become quite hot during operation, which

could cause personal injury.