6 . Install the flexible probe by threading it clockwise onto the threaded brass bushing

around the sensor until it is finger tight .

caution: to prevent personal injury and equipment damage, neVeR

operate the unit without the flexible probe correctly installed. sensor

contamination, erratic performance, and other problems may occur.

additionally, the sensor will become quite hot during operation, which

could be dangerous.

PRobe tiP anD filteR
The pointed tip of the flexible probe is removable for cleaning and access to the filter

cartridge (see Figure 9) . Once the tip is removed, access to the filter cartridge is

possible .

1 . Remove the probe tip by firmly grasping both the probe and the tip and rotating the

tip counterclockwise .

2 . Inspect the filter inside the filter cartridge . If any discoloration or particulate is visible,

the filter cartridge should be discarded and replaced . A pack of replacement filter

cartridges is included with your unit; refer to the Replacement Parts section to order

additional cartridges .

Filter Cartridge

Install as shown .

Tip

O-Rings

Probe Assembly

Fig . 9

Fig . 8

Threaded Bushing

Pins

Sensor