Vanguard VCBA S2 (DigiTMR S2, DigiTMR S2 PC, CT-6500 S2, CT-7000 S2, CT-7500 S2, CT-8000) User Manual

Page 40

Advertising
background image

VCBA S2 VERSION 4.xx SOFTWARE MANUAL

REV 3

37

area. Once enabled, the value from the cursor position (63.118 ms) will be inserted in
the input area as shown below:

5. Click on the “OK” button. The override value will be inserted in the tabulated test

results. The value will be marked with an asterisk (*) to indicate that the calculated
value was overridden:

The above method works well for simple tests such as an OPEN or CLOSE test. For more
complex situations such as a CLOSE-OPEN test with an insertion resistor, you can manually
input the override values. To manually input the override values:

1. Retrieve the test record that you would like to view.

2. Press the [F8] key.

3. The “Contact Override” windows will be displayed as in the previous example above.

Select the contact number from the “Contact:” dropdown list.

4. Click on the “Enable” checkbox next to each value you would like to override for the

selected contact, and then enter the override value in the input area to the left of the
checkbox.

5. Click on the “OK” button and all enabled override values will be inserted in the

tabulated test results.

Advertising