Vanguard VCBA S2 (DigiTMR S2, DigiTMR S2 PC, CT-6500 S2, CT-7000 S2, CT-7500 S2, CT-8000) User Manual

Page 77

Advertising
background image

REV 3 VCBA S2 VERSION 4.xx SOFTWARE MANUAL

74

6.2

Performing a Static Resistance Test

1. Make sure the VCBA S2 software is running. Connect the CB analyzer to the PC via either

the RS-232C or USB port.

2. The CB analyzer should enter Computer Interface Mode.

3. Click on the Run icon in the Test command group in the Command Ribbon. The

following window will be displayed:

4. From the “File Information” section, click on the folder icon and select the folder on

your computer where you would like to save the test record.

You can type a filename prefix in the “Filename” input field. This can be any text that
will be helpful to you in identifying your test records. If you would like the date to be
added to the filename, check the “Add Date” checkbox. Also, to ensure that filenames
are unique, check the “Add ‘001’ to ensure uniqueness” checkbox.

5. From the “Shot Type” section, click on the “Static Resistance” radio button.

6. Select the desired timing window from the “Timing Window” options.

Advertising