Interface programming, Board set up and programming – Warner Electric MCS-131 User Manual

Page 5

Advertising
background image

Interface Programming

The two optional logic modules provide for expanded input switching of the basic control. Logic board
selection will be dependent primarily upon the input switching requirements. For most applications, the
bag logic module will be the more suitable.

Board Set Up and Programming

A. Bag Logic Board, 6040-448-016

Switch No.

Function Affected

Control Operation

SW 1

Stop

Open: Pulse Control on terminal 7. Triggers on negative
transition of input pulse.

SW 2

Photo Input

Closed: Dark Operation, switches

SW 3

Open: On negative transition

SW2

Photo Input

Open: light Operation, switches

SW 3

Closed: On positive transition

SW4

Start

Open: Pulse Control on terminal 1. Triggers on negative
transition of input pulse.
Closed: Level input on terminal 1. Active low, triggers on
negative transition of input.

Using the Bag Logic Module, 6040-448-016, control input terminal designations change somewhat as
shown in Figures 3 and 4.

Terminal No.

Function

Control Input Logic

1

Start

Selectable on Card for Level or Pulse

2

Photo Inhibit

Level only, Active Low

7

Stop

Selectable on Card for Level or Pulse

8

Photo Input

Level, Light/Dark Card Selectable

For waveform timing diagrams, see Figure 5.