Warner Electric MCS-131 User Manual

Page 7

Advertising
background image

50

6

0

50

6

0

0 to 6

CH1

(Clutch)

CH2

(Brake)

Adjustable Over Excitation

Time 2 to 14 MSEC.

Adjustable For

Steady State Output

0.1 10 17 MSEC.

Adjustable Delay

To Prevent Overlap

Current

Voltage

DC

+24V COM +4.8V

18 17 16

Switching

S1- Input Switch

Open - Channel 2 ON

Closed - Channel 1 ON

Inhibit Switch

Open - System Inhibited, Channel 1 ON

Clesed - Normal Operation

S2-

120 V

or

240V

AC

AC

Input

Earth

GND

DC

COM +12 V CH2 CH1 IN

N/C

-

-

+

+

CH2

CH1

INH N/C

S1

S2

MCS-131

TERMINAL DESIGNATIONS
1 NO. Connection

2 Inhibit

3

4

5

6

7 NO. Connection

8 Input

9 LED Channe1 1

10 LED Channel 2

11 +12 VDC Output

12 DC Common

13 Earth Ground

14

15

16 +4.8 VDC Output (Optional Board)

17 DC Common

18 +24 VDC Output

Channel 1 Output

Channel 2 Output

AC Input

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

LED

Figure 1 - Voltage and Current Waveforms

Figure 2 - Basic Control with Switch Inputs

Warner Electric • 800-825-9050

P-262 • 819-0493

6