Warner Electric MCS-131 User Manual

Page 8

Advertising
background image

DC

COM

+24V

+4.8V

AC

INPUT

EARTH

GND

DC

COM

+12V CH2

LED

CH1 P.E. STOP

CH 2

CH 1

INH START

OPTIONAL LOGIC BOARD 6090-448-016

MCS-131

120 V

OR

240V

AC

120 V

OR

240V

AC

MCS-638

S3

S3

S2

S2

S1

S1

SWITCHING
S1 - START INPUT SWITCH
S2 - PHOTOELECTRIC INHIBIT SWITCH
S3 - STOP INPUT SWITCH
NOTE: INPUT SWITCHING DEPENDENT ON
SWITCH SETTINGS ON LOGIC BOARD, PART NUMBER 6040-448-016

SWITCHING
S1 - START INPUT SWITCH
S2 - PHOTOELECTRIC INHIBIT SWITCH
S3 - STOP INPUT SWITCH
NOTE: INPUT SWITCHING DEPENDENT ON
SWITCH SETTINGS ON LOGIC BOARD, PART NUMBER 6040-448-016

TERMINAL DESIGNATIONS

+

+

_

_

1. START INPUT
2 PHOTOELECTRIC INHIBIT
3
4
5
6
7 STOP INPUT
8 PHOTOELECTRIC INPUT
9 LED CHANNEL 1
10 LED CHANNEL 2
11 +12 VDC OUTPUT
12 DC COMMON
13 EARTH GROUND
14
15
16 +4.8 VDC OUTPUT (Optional Board)
17 DC COMMON
18 +24 VDC OUTPUT

1. START INPUT
2 PHOTOELECTRIC INHIBIT
3
4
5
6
7 STOP INPUT
8 PHOTOELECTRIC INPUT
9 LED CHANNEL 1
10 LED CHANNEL 2
11 +12 VDC OUTPUT
12 DC COMMON
13 EARTH GROUND
14
15
16 +4.8 VDC OUTPUT (Optional Board)
17 DC COMMON
18 +24 VDC OUTPUT

CHANNEL 1 OUTPUT

CHANNEL 1 OUTPUT

CHANNEL 2 OUTPUT

CHANNEL 2 OUTPUT

AC INPUT

AC INPUT

+

+

+

+

_

_

_

_

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

TERMINAL DESIGNATIONS

+24V

DC

COM +4.8V

POWER SUPPL

Y

6040-448-016

AC

INPUT

EARTH

GND

DC

COM +12V

LED

CH2 CH1 P.E. STOP

CH2

CH1

INH START

+

+

_

_

OPTIONAL LOGIC BOARD 6040-448-016

MCS-131

MCS-624

18

17

16

15

14

13

12

11

10

8

7

9

6

5

4

3

2

1

Figure 3 - Expanded Input Switching with Logic Board, 6090-448-016 and MCS-638

Color Mark Scanner

Figure 4 - Expanded Input Switching with Logic Board 6040-448-016 and MCS-624 Mark Reader

Warner Electric • 800-825-9050

P-262 • 819-0493

7