B. Switch Logic Module, 6040-448-017

This module expands the input capabilities of the basic MCS-131 Control. For most application, however, the
Bag Logic Module, 6040-448-016, will be used.

Switch No.

Function Affected

Control Operation

1

Always Closed

----------

2

Input Signals

Open: Pulse Control
Closed: Level Control

3

Not Used

4

Always Closed

----------

Using the Stitch Logic Board, 6040-448-017, switching inputs change somewhat from the basic MCS-131
Control. Input switching configurations are shown in Figure 6.

Terminal No.

Function

Control Input Logic

1

Start

Pulse or Level

2

Inhibit

Level only, Active Low

7

Stop

Pulse or Level

For waveform timing diagram, see Figure 7.

Cautions

Fusing:

For 120 VAC operation a 1.6A slo-blo fuse should be used.
for 240 VAC operation a 1.0A slo-blo fuse should be used.

Note: When replacing a fuse, the same type and size as specified should be used to prevent
control damage.

AC:

AC line voltages are present at the terminal strip.