Warner Electric MCS-131 User Manual

Page 9

Advertising
background image

CH 2

CH 1

ON

ON

ON

ON

OUTPUTS

SWITCHING SIGNALS

START

SCANNER

SCANNER

INHIBIT

STOP

6040-448-016 SWITCH PROGRAMMING

Open: The

output f.f. goes low, ligic “0” at the negative transition

of the “stop” inut. It may be immediately retriggered.

Closed: The

output f.f. goes low, ligic “0” at the negative transiotion

of the “stop” input and remains low as long as this

input is low.

Open: The

scanner input must be low, logic “0”, and go hight,

Closed: logic “1” when a mark is detected.

Closed: the scanner input must be high, logic “1”, and go low,

Open: logic

“0” when a mark is detected.

Open: The

output f.f. trips high, logic “1” at the negative

transition of the “start” input.

Closed: The

information in the output f.f. remains latched after the

negative going transition of the “start” input.

SW 1

SW 2*

SW 3*

SW 2*

SW 3*

SW 4

* Only one of the two switches may be closed.

OPTIONAL LOGIC BOARD 6040-448-017

MCS-131

START

INH

CH 1

CH 2

STOP

N.C.

CH1

CH2

LED

+12V

DC

COM

EARTH

GND

AC

INPUT

+

+

-

-

DC

COM

+24V

+4.8V

18

17

16

120 VAC

OR

240 VAC

15

14

13 12

11

10

9

8

7

6

5

4

3

2

1

S2

S3

S1

SWITCHING

S1 - START INPUT SWITCH

S2 - STOP INPUT SWITCH

S3 - INHIBIT INPUT SWITCH

NOTE: SWITCHING LOGIC DEPENDENT ON SWITCH

SETTINGS ON LOGIC BOARD 6040-448-017

TERMINAL DESIGNATIONS

1. START INPUT

2 INHIBIT

3 +

4 -

5 -

6 +

7 STOP INPUT

8 NO. CONNECTION

9 LED CHANNEL 1

10 LED CHANNEL 2

11 +12 VDC @ 100 MA.

12 DC COMMON

13 EARTH GROUND

14 -

15 -

16 +4.8 VDC OUTPUT (Optional Board)

17 DC COMMON

18 +24 VDC OUTPUT

CHANNEL 1 OUTPUT

CHANNEL 2 OUTPUT

AC INPUT

Figure 5 - Input - Output Switching Relationships with Logic Board 6040-448-018

Figure 6 - Extended Input Switching With Logic Board 6040-448-017

Warner Electric • 800-825-9050

P-262 • 819-0493

8

Advertising