6. Input/Output Configuration

The “Input/Output” tab allows you to set-up the XCTRL Input/Outputs depending of your application
requirements. The XCTRL is able to handle two types of digital Input/Output : the NPN and the PNP type.
This hardware set-up defines the activation level of the splice Inputs (A,B,C,Sync), of the partition inputs (P1,
P2, P3), as well as the Digital (ErrS1, ErrS2) and Analog (Out1, Out2) outputs.

This configuration menu will affect the correct behavior of all Input/Output of the XCTRL.
So care must be taken with it!

Note: All states of the inputs and outputs are displayed in the Real Time window and Input/Output window.
Please refer to the Diagnostic tools tab for more information.

• Digital Input settings


Select in this tab the polarity type for A, B, C StpInt and P1, P2, P3 inputs. Two kind of polarity (1L) are
available: PNP (24V) and NPN (0V) :

- PNP: Logical active State : 1L = 24V. The low state 0L will be at 0V or GND.

- NPN: Logical active State : 1L = 0V. The low state 0L will be at 24V.

For all digital inputs, the polarity selection is common to all partitions. So any changes to a partition will be
automatically copied and pasted to all other partitions.

The “Sync Input” drop down menu allows the selection of the “Latch mode” of the ABC Inputs. When “Sync
Input” becomes active, the state of all ABC Inputs is transferred into the controller and processed.