Rapid-Air SERVO FEED WITH CUT-TO-LENGTH: 100, 200 & 300 SERIES User Manual

Page 20

Advertising
background image

19

Pressing the F4 key, stops the automatic cycle and the main menu screen appears.
When the automatic screen is displayed, all keys except the F4 key are inactive. Every
time the press cycles and trips the feed switch, the feed will cycle once per the
parameters displayed on the screen. If the feed encounters excessive material drag
while feeding or the material being moved encounters a restriction that stops the
material forward movement then a servo fault can occur. If this happens then the
following screen is displayed.

DRIVE FAULT OCCURED
NOTE TYPE OF FAULT—-
(xxx)


Example of fault - (2) = motor over temperature

Look up fault code printout listed in this manual.

To reset the fault, the master on-off switch has to be cycled which will reset the
controller. The material path should be checked for obstruction and parrallelism to the
die. If all this seems to be satisfactory and another fault occurs the factory should be
consulted.

MAIN SELECTION MENU
F1=JOB # F2=MANUAL
F3=AUTOMATIC CYCLE
F4=REVIEW JOB PROGRAM


The last section to be covered is the ramp/counters section. To get into this mode,
press the ramp push-button and the following screen appears.

SELECT RAMP/COUNTERS
F1=BATCH/TOTAL COUNT
F2=ACCEL/DECEL RAMPS
F4=EXIT TO MAIN MENU

F1=BATCH/TOTAL COUNTS

Pressing the F1 key will bring up the batch/total screen, which is used for presetting
the batch count or resetting the total count. The following screen appears.



BATCH COUNTER=000000
TOTAL COUNTER=000000
SET:F1=BATCH F2=TOT
F4=RETURN TO RAMP COUNT

Advertising