6. No AC voltage at DC drive board.

a. Check wiring.

7. Check Signal voltage between P2 to I2 on DC drive while moving dancer
arm.

0-6 VDC—Ramm

0-9 VDC—Regen Drive

a. If there is a signal, check continuity between I1 & I2.

If continuity, replace 69100035 board or call factory.

If no continuity, replace D.C. drive or call factory.

8. Check line voltage input of 69100034 board, 120 VAC, TB-1

a. Check wiring. Call factory.

9. Check pico fuse 69100034 board (f1).

a. Replace fuse—call factory.

10. Check for 0—12 VDC between pin #1 (+V) and pin #2 (GND) of panduit
connector TC3 on board #69100034.

a. If no voltage present call factory.

11. Check for DC voltage between pin #6 (V0) and pin #2 GND of panduit
connector TC3, on board #69100034, while moving the dancer arm from
minimum to maximum position.

a. If voltage is present, turn power off and check the ribbon cable