Rapid-Air PALLET MASTER (PMD): PMD35 & PMD50. 115VAC, 1PH, 60HZ User Manual

Page 25

Advertising
background image

Rapid Air Corporation

5.

Nominal trimpot settings are as follows (expressed in % of full CW

rotation):

TABLE 1: NOMINAL TRIMPOT SETTINGS

MIN (minimum speed): 15% CL (current limit/torque): 65%

MAX (maximum speed): 65% ACCEL (acceleration start): 20%

IR (IR compensation): 25% DECEL (deceleration stop): 20%

PLUG IN HORSEPOWER RESISTOR

A Plug-In Horsepower Resistor must be installed to match the RAMM to
the motor horsepower and voltage. See table 2 for the correct value. Plug-In
Horsepower Resistors are stocked by your distributor.