Programming

Rev 1.0

January 2014

29

Hose Selection — After the dispenser number is chosen, Hose 1 is indicated on the display.

From this point, the following parameters may be set for Hose 1. If programming a multi-

product dispenser, parameters must be set for all hoses.

Product — Press the <GRADE> key to scroll to the desired product for the current hose

displayed. During this step, pressing the <AUTHORIZE> key will clear the product

number for reentry.

Service — To select service type, press <CHANGE> key to toggle between Full- or Self-

Service. Setting service type on one hose selects it for the entire dispenser.

Slowdown Amount — To set slowdown amount, enter new value on the numeric keypad.

Setting slowdown amount on one hose sets it for the entire dispenser. Default is 15 cents.

Maximum is 99 cents.

If the dispenser is a multi-product dispenser, press <SELECT> to scroll to the next hose to

be programmed. Follow this procedure to program each hose of each dispenser at the site.

To exit Program Mode PGM 2, press <MANAGER> key. PGM 0, the mode entry prompt,

will appear on the display. To return to operator mode, press <MANAGER> key again.

Program Mode PGM 3 — Product Name Assignment

In this mode, Product Name for each product at the site is programmed. To enter this mode

from the PGM 0 mode number prompt, press <3> on the numeric keypad and then press

<ENTER>.