Function key editor – Maple Systems MAPware-100 User Manual

Page 25

Advertising
background image

If the Current Message Register is enabled, an address must be specified in the Address text

box. Pressing the Default button, resets the address to the default address which is two

greater than the address set in the Message group box in the Configuration Editor.
The value in the Current Message Register will either be in decimal or BCD format. It

depends on whether the BCD Format check box in the Message group box in the

Configuration Editor is checked.

Password Editor

Clicking on the Editor button within the Passwords box will display the following window:

The setup password is used to gain access to the OIT’s setup menu where local parameters

may be set as well as downloading from the PC.

Note: Make sure you remember the setup password! If you lose it, you will be unable to

download new configuration data or firmware to the OIT!

If the default setting (00000) is selected for the setup password, the operator can enter the

setup menu by entering five 0’s, or using a shortcut which is simply pressing the Enter key.

Function Key Editor

The Function Key Editor button is the shortcut for the Tools/Function Key Editor menu item.

The OIT has 12 or 16 programmable function keys, depending on the model. Each key has

the ability to be programmed as disabled, push on-push off, momentary, message display, or

latched. See the MAP Family Operation Manual for a description of each Function Key

mode. Clicking on the Function Keys button will display the function key editor screen:

24

OPERATION

1010-0089, REV00