1 flex network specifications, 1 flex network interface (connector), 1 flex network specifications -2 – Proface AGP3500 - 10.4 DIO HMI" User Manual

Page 163: 1 flex network interface (connector) -2

Advertising
background image

GP3000 Series Hardware Manual

6-2

This section describes the FLEX NETWORK Connector packaged with the FLEX NETWORK board type

unit of the GP3000 series.

This connector is an accessory of the GP unit. It is also offered as an optional maintenance item by Pro-face.

6.1

FLEX NETWORK Specifications

Connect the FLEX NETWORK Connector (accessory) to the GP unit and then connect I/O units or other

FLEX NETWORK units.

6.1.1

FLEX NETWORK Interface (Connector)

SEE

2.3 Optional Items for the FLEX NETWORK Board Type (page 2-7)

When you use the FLEX NETWORK board type unit of the GP3000 series, read this section in

conjunction with the specifications of your GP series (Chapter 4).

This section describes the information specific to the FLEX NETWORK board type unit of the

GP3000 series.

The information common to the standard type and FLEX NETWORK board type units of the

GP3000 series is described using the model of the standard type.

(Example) For information about model AGP3500-T1-D24-FN1M, read the information about

the standard type model “AGP-3500T”.

Applicable connector

284510-6 <Tyco Electronics AMP.>

Pin Arrangement

Signal Name

Description

1

TR

+

CH1 communication data

2

TR

CH1 communication data

3

SLD

CH1 cable, shielded wire

4

TR

+

CH2 communication data

5

TR

CH2 communication data

6

SLD

CH2 cable, shielded wire

6 5 4 3 2 1

(Cable connection side)

Advertising