Chapter 7 CANopen Interface

7-3

7.1

CANopen Specifications

7.1.1

CANopen Interface

7.1.2

CANopen Data Transfer Settings

CANopen is the networking concept based on the international standard CAN. CANopen is defined as a uni-

form application layer by the DS 301 specifications of the CiA (CAN in automation).

7.1.3

CANopen cable arrangement

The CANopen interface uses D-sub 9-pin plug connector. The plug is assigned with the CAN_H, CAN_L and

CAN_GND connections. CAN_H and CAN_L are two physically different bus levels. CAN_GND is the

common reference potential.

Connector (GP unit side)

XM2C-0942-502L <OMRON Co.>

Recommended Cable Connector (Cable side)

See page 7-5.

Interfit Bracket

#4-40 (UNC)

Pin Arrangement

Signal Name

Meaning

1

-

2

CAN_L

CAN-L bus line

3

CAN_GND

CAN ground

4

-

5

-

6

-

7

CAN_H

CAN-H bus line

8

-

9

-

Shell

FG

Frame Ground (Common with SG)

Communication Type

1:N

Connection Method

Bus

Transfer Method

CSMA/NBA. Half-duplex serial transmission.

Transfer distance
speed/Transmission
length

No. of nodes

63 nodes max. Bit variable input: 512 points

*1

, Bit variable output:

512 points

*1

, Integer variable input: 128 points

*2

, Integer variable

output: 128 points

*2

.

*1

When using GP-Pro EX under Ver.2.50, Bit variable enables to input/output 256 points.

*2

When using GP-Pro EX under Ver.2.50, Integer variable enables to input/output 64 points.

1

(GP Unit Side)

6

9

5

Baud rate

*1

*1 Set the baud rate with the software.

Bus length

1000 kbps

20m

800 kbps

40m

500 kbps

100m

250 kbps (factory settings)

250m

125 kbps

500m

50 kbps

1000m