Chapter 8 Installation and Wiring

8-31

8.6

Installation and Removal of Function Expansion Memory

8.6.1

GP-3400 Series

„Items to prepare

Function Expansion Memory (Model: GP3300-EXDM01)

One pair of clean (preferably new) cotton gloves.

Antistatic wrist strap

Phillips screwdriver (no.2)

„Installation method

(1)

Turn off the power to the GP unit. Unplug the power cable from the main power supply.

• Models that can mount Function Expansion Memory are as indicated below.

• GP-3400 Series

• GP-3500 Series

• GP-3600 Series

• GP-3700 Series

Operate after confirming power is not being supplied to the GP. Failure to do so may cause electric

shock or device damage.

The Function Expansion Memory, the GP’s inner circuit board and other components are precision

mechanical equipment, which are extremely weak to static electricity. Be sure to wear an antistatic

wrist strap. Failure to do so can be cause for malfunction.

The Function Expansion Memory, the GP’s inner circuit board and other components are precision

mechanical equipment. Do not touch unnecessary areas when operating. Failure to do so can be

cause for malfunction.

Be sure not to exert strong force on the Function Expansion Memory. Failure to do can be cause

for damage.

• Remove the GP unit from the equipment to which the unit has been incorporated,

and work with the GP unit with the display surface facing downward. Be sure to

perform work on a flat area. This will prevent damage to the GP unit.

• Be sure to protect the display surface to prevent damage during the operations.

Advertising