PS-3000B Series Hardware Manual

2-14

Switch

Number

Description

ON

OFF

RS-232C

RS-422

RS-485

1

Changes COM2’s
communication
method

RS-232C

RS-422 / RS-485 ON

OFF

*1

*1

Be sure to keep the settings, “OFF” for RS-422 or RS-485.

OFF

*1

2

Changes COM2’s
communication
method

RS-422 / RS-485 RS-232C

OFF

ON

ON

3

Changes COM2’s
communication
method

RS-422 / RS-485 RS-232C

OFF

ON

ON

4

Changes TX data’s
output mode

TX data output is
controlled via the
RTS signal.

TX data output is
NOT controlled
via the RTS
signal. (normally
output)

OFF

ON/OFF

ON/OFF

*3

5

Switches the TX
termination
resistance ON/OFF

Inserts
termination
resistance of
220

Ω between

TXA and TXB.

No termination

OFF

ON

ON/OFF

*2

*2

If you use the termination resistance, base your settings on the connection specifications.

6

Switches the RX
termination
resistance ON/OFF

Inserts
termination
resistance of
220

Ω between

RXA and RXB.

No termination

OFF

ON

ON/OFF

*2

7

Switches the
shorting of TXA
and RXA ON/OFF

Shorts TXA and
RXA.
(RS-485 mode)

No shorting
(RS-422 mode)

OFF

OFF

ON

8

Switches the
shorting of TXB
and RXB ON/OFF

Shorts TXB and
RXB.
(RS-485 mode)

No shorting
(RS-422 mode)

OFF

OFF

ON

9

RTS Automatic
control mode
(enabled only when
RS-485 mode)

The data is
automatically
controlled via the
RTS signal.

The data is not
automatically
controlled via the
RTS signal.

OFF

OFF

ON/OFF

*3

*3

To control TX output driver via RTS automatically, set ON. Be sure to set SW No.4 OFF.

To control TX output driver via RTS signal, set OFF. Be sure to set SW No.4 ON.

10

OFF

OFF

ON/OFF

*3

Table2) Serial Mode Select Switches