Proface APL3000B - Node Box PC User Manual

Page 60

Advertising
background image

Chapter 3 PS-A Monitoring Features

3-7

‹ External Output Signal

The PS-A’s RAS interface connector uses the following output signals.

General-Purpose Output (DOUT 4 bits)

This general purpose digital output signal provides system condition information to external devices.

The System Monitor property of the control panel or the API-DLL is used by applications to control this signal.

The above mentioned general purpose digital output signals provide system condition information to

external devices.

The System Monitor property can be used to enable or disable any of these output signals.

Rated Voltage

DC12V to 24V

Maximum Load Current

120mA/point

Out Voltage Drop

1.5V or less( at 100mA load current )

Output Points

4 points

Isolation Method

Photocoupler Isolation

Dielectric Strength Voltage

500V or more

External Power Supply

DC12V / 200mA, DC5V/100mA

• Be sure to operate the unit within its maximum load current. If the maximum load

current exceeds this range, a malfunction or PS-A damage may occur.

• Design your electrical system by adding the load current and voltage values to the

terminal voltage. If load current value used is large, the voltage drop of 1.5V or less

will occur between the terminals.

• When connecting an induction load, be sure to connect the above drawing’s

protection diode (*1).

For connection pin location details,

+5V

R

PC357

4.7kΩ

SSTA06

Cable

*

1

DC12V

to

24V

DOUT2(+) pin # 8
DOUT0(+) pin # 10
DOUT1(+) pin # 20
DOUT3(+) pin # 22

DOUT2(-)

pin # 7

DOUT0(-)

pin # 9

DOUT1(-)

pin # 19

DOUT3(-)

pin # 21

( Interface Circuit )

Load

SEE

PS-3710A/PS-3711A Series Hardware Manual 2 Specifications