PS-3710A / PS-3711A Reference Manual

4-4

The touch position recognized in
the touch panel still deviates
from the actual touch even after
calibration.

If the touch position still deviates after calibration, possible
causes are:
• There are flaws or unevenness on the surface of the PS-A.
-> If the bracket securing the PS-A is tightened too much,

flaws or unevenness may result. Release the PS-A from
the bracket and check whether the problem continues.

• The touch panel calibration was not finished properly.
-> Uninstall the touch panel driver once, and then install the

latest driver. The latest driver can be downloaded from the
Pro-face support site “Otasuke Pro!”.

• The hardware in the touch recognition section is faulty.
-> Use the PS-A that operates properly and check whether

the same problem occurs. If the problem occurs only with
a specific unit, contact your local PS-A distributor for repair
or replacement.

I want to know what the LED
indicator indicates.

A Touch Panel Self-Test Error
occurred.

The touch panel is faulty. Please contact your local PS-A
distributor.

A “Smart Alert” occurred

Predicts the malfunction and life expectancy of the hard disk/
SSD/CF. It is recommended that the disk be replaced before
experiencing malfunction or reaching the end of its life.

Problem

Countermeasure and reference page

SEE

‹

LED Indicator (page3-5)